Lab 17 Amino Acids and Proteins Lab date 10/22/2013 12-1350 I Purpose The purpose of this experiment was to separate mixtures of II Method For a complete list of experimental procedures see prelab outline attachment #1. “For a complete list of experimental procedure see Seager‚ Spencer L. and Slabaugh‚ Michael R. Safety-Scale Laboratory Experiments for Chemistry for Today General‚ Organic and Biochemistry; Thomson Brooks/Cole‚ Belmont‚ CA‚ USA‚ 2008; pp.221-225”. III Data Part A Mass
Premium Experiment Chemistry Cholesterol
Lab Report – Strong Example Problem/Question Does using a base coat before painting nails prevent chipping? Background Information When painting nails‚ some manicurists use a base coat before applying the polish. The purpose of a base coat is to help the polish stick to your nails more easily. Base coats also help to protect your natural nail from the staining effects of colored polishes. Ridge-filling base coats fill in the grooves and cracks in the nail to create a smoother appearance
Premium Left-handedness French Revolution Handedness
CE121: Construction Materials Laboratory Report No. 1 Particle Size Distribution Van Joseph E. Casalme 2010-14928‚ BS Civil Engineering Institute of Civil Engineering‚ College of Engineering University of the Philippines Diliman‚ Diliman Quezon City 1101 Submitted to: Engr. Christian R. Orozco ABSTRACT This test (ASTM C136-06) determines the grading of materials being used as aggregates using two parameters (coefficient of uniformity and gradation) from particle-size distribution
Premium Sieve analysis Particle size distribution Construction aggregate
Solute Concentration of Potatoes Lab #1 Purpose: To find the molarity/concentration of potato cytoplasm. Materials: As on page 1 in the lab handout. Procedure: As on page 1 in the lab handout. Data and Observations: Test Tube # | Concentration of sucrose solution (mol/L) | Initial Mass (g) | Final Mass | Percentage change in mass | 1 | 1.0 mol/L | 3.00g | 2.25g | -25.0% | 2 | 0.9 mol/L | 2.70g | 2.07g | -23.3% | 3 | 0.8 mol/L | 2.92g | 2.25g | -22.9% | 4 | 0.7 mol/L | 2.60g
Premium Concentration Osmosis Chemistry
simple mechanisms used to convert rotary motion into oscillating linear motion and vice-versa. The first of these is the slider-crank - a mechanism widely used in engines to convert the linear thrust of the pistons into useful rotary motion. In this lab we will measure the acceleration of the piston of a lawn mower engine at various speeds. The results exemplify a simple relation between speed and acceleration for kinematically restricted motions‚ which will discover. An adjustable slider-crank apparatus
Premium Internal combustion engine Classical mechanics Crankshaft
Abstract This lab’s purpose was to test the patterns of percolation in various places. This lab tested how soil would absorb water based on different places. Distance from a group of trees‚ distance from a swamp‚ and different types of soil were tested. From the results collected‚ you can not prove‚ but you can infer that the ability to absorb increases as you go farther away from a swamp‚ and a group of trees. The ability to absorb also increases based on how much silt is in soil. Introduction
Premium Soil Surface runoff Digestion
Coulomb’s Law Purpose: The purpose of this lab was to demonstrate that the force between two stationary charges is directly proportional to the product of the charges and inversely to the square of the distance between them. Coulomb’s law tells us that the force between two charges depends (1) linearly on the strength of each charge‚ and (2) inversely on the square of the distance between them. Mathematically we would write this as . Procedures Part1 Begin by removing the right side
Premium Electric charge
conducted on 13th August 2008 in Machines Dynamics Laboratory. The experiment was conducted in groups of four‚ and was supervised by lecturer Mr. Mohd Azahari Johan. Conducting this experiment is for fulfilling the requirements of Applied Mechanics Lab (MEC 424). A pendulum is defined as body so suspended from a fixed point as to swing freely to and from by the alternate action of gravity and momentum. It is used to regulate the movements of clockwork and other machinery. Therefore‚ a compound
Premium Pendulum
the period of oscillations to the length of the pendulum.Sources of error for this procedure included precision in both length and time measurement tools‚ reaction time of the stopwatch holder‚ and the accuracy of the stopwatch with respect to the lab atomic clock. The final result of g takes into account the correction for the error introduced using the approximation. There are opportunities to correct for the effects of mass distribution‚ air buoyancy and damping‚ and string stretching[1]. Our results
Premium Regression analysis Measurement Normal distribution
Abstract……………………………………………………………………………………………2 Introduction………………………………………………………………………………………..2 Background………………………………………………………………………………..2 Objectives…………………………………………………………………………………2 Scope………………………………………………………………………………………3 Theory review……………………………………………………………………………………..3 Design of report…………………………………………………………………………………...5 Procedures…………………………………………………………………………………………5 Results……………………………………………………………………………………………..6 Discussion…………………………………………………………………………………………6 Conclusion………………………………………………………………………………………...7 Reference………………………………………………………………………………………
Premium Fluid dynamics