Preview

How to choose industrial steam boiler

Good Essays
Open Document
Open Document
409 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
How to choose industrial steam boiler
With the steam needed for industrial production, more and more demand for industrial boilers also increase. Industrial steam boiler can take natural gas, coal, biomass, oil as fuel. ZG is a professional industrial steam boiler can according to the needs of customers’ development and reasonable conduct to manufacture industrial steam boilers for them.

In the purchase process of industrial steam boiler, companies need to pay attention to the technical parameters of the model of the boiler, which is the basis of the reference that companies need to focus on. This article from the rated evaporation of industrial steam boilers (t / h), rated steam pressure (MPa), rated steam temperature (℃), water temperature (℃), applicable to analyze industrial steam boilers:

Rated evaporation:
Rated evaporation refers to industrial steam boiler’s steam production per unit of time, generally in tonnes or kilograms as a unit. In the purchase of industrial steam boilers, The most important thing is to understand the power of a steam boiler, which is the nominal amount of evaporation.

Rated steam pressure:
Rated steam pressure is the pressure of the steam, the steam used in various processes or other aspects are required to have a certain amount of pressure with steam. Meanwhile, since we are generally usually use saturated steam, saturated steam pressure and the steam temperature of the steam to a constant ratio, so we generally use a control pressure is to control the temperature of steam of the steam.
Rated steam temperature:
In the technical parameters of industrial steam boiler, steam pressure and steam temperature is corresponding. In 1.25MPa, the temperature of the steam generated in the steam pressure is 194 ℃. If necessary to control the steam temperature, steam pressure can be controlled to achieve.
Water temperature:
Water temperature is added to industrial steam boiler’s water temperature.
Applicable fuel:
Industrial steam boilers are available for

You May Also Find These Documents Helpful

  • Satisfactory Essays

    documentation

    • 457 Words
    • 2 Pages

    Boiler and Pressure Vessels Regulation govern to the design, construction, maintenance, use, operation, repair and service of boilers, pressure vessels and Piping in the province of Ontario.…

    • 457 Words
    • 2 Pages
    Satisfactory Essays
  • Powerful Essays

    -Steam because more burn,at the same temperature water vapor(steam)contains more heat than liquid water(boiling water).In addition,to sensible heat steam contains latent heat due to phase change.Boiling water contains sensible heat only thermodynamics.…

    • 1369 Words
    • 6 Pages
    Powerful Essays
  • Good Essays

    The objective of this experiment is to determine the relationship between saturation pressure and saturation temperature of the wet steam.…

    • 1148 Words
    • 5 Pages
    Good Essays
  • Satisfactory Essays

    3. Determine the specific volume of superheated water vapor at 10 MPa and 400°C, using (a) the ideal-gas equation, (b) the steam tables. 4. Determine the specific volume of superheated water vapor at 3.5 MPa and 450°C based on (a) the ideal-gas equation, (b) the steam tables. 5. A 3.27-m3 tank contains 100 kg of nitrogen at 175 K. Determine the pressure in the tank, using (a) the ideal-gas equation. Compare your results with the actual value of 1505 kPa. 6. A 1-m3 tank contains 2.841 kg of steam at 0.6 MPa. Determine the temperature of the steam, using (a) the idealgas equation 7. A piston–cylinder device initially contains 0.07 m3 of nitrogen gas at 130 kPa and 120°C. The nitrogen is now expanded to a pressure of 100 kPa polytropically with a polytropic exponent whose value is equal to the specific heat ratio (called isentropic expansion). Determine the final temperature and the boundary work done during this process. 8. A mass of 5 kg of saturated water vapor at 300 kPa is heated at constant pressure until the temperature reaches 200°C. Calculate the work done by the steam during this process. 9.…

    • 1061 Words
    • 5 Pages
    Satisfactory Essays
  • Good Essays

    The table value of the latent heat of the vaporization of water is 2300000 J/kg, which means: To change each kilogram of water into steam, 2300000 J are required to be transferred.…

    • 1087 Words
    • 5 Pages
    Good Essays
  • Powerful Essays

    Air Conditioning

    • 2043 Words
    • 12 Pages

    The main purposes of this experiment are to allow students to get familiarized with air conditioning system and also to obtain experimental data so that the state point can be plotted on a psychrometric chart. The apparatus used in this experiment are SOLTEQ air-conditioning module (Model:HE166-02) which is designed to work with the Base Condensing Unit. The major part of the evaluation procedure is carried out with the aid of psychrometric chart. Thus, the heating power, cooling power and steam enthalpy can be calculated through the experiment.…

    • 2043 Words
    • 12 Pages
    Powerful Essays
  • Better Essays

    Chemical Engineering

    • 3228 Words
    • 13 Pages

    This Aspen Plus model simulates the production of acetic acid by low pressure methanol carbonylation in the presence of a heterogeneous rhodium (Rh) catalyst and the promoter methyl iodide. It is intended to resemble the Chiyoda/UOP Acetica™ process, a novel heterogeneous methanol process for the production of acetic acid. This technology is based on a heterogeneous Rh catalyst in which the active Rh complex is chemically immobilized on a polyvinylpyridine resin. In the Aspen Plus model, the plant (base case) is designed to produce 800 million lb/yr (363,000 t/yr) of acetic acid from methanol carbonylation. The process consists of both the carbonylation and purification sections. Results from the Aspen Plus simulation shows that the purity of acetic acid obtained is 98.4%. Vent gas (4,304 lb/hr) from two absorbers and heavy by-products (1,150 lb/hr) from the bottom of the heavy-ends stripper are sent to incinerator. The process also generates approximately 65,000 lb/hr of low-pressure (150 psig)…

    • 3228 Words
    • 13 Pages
    Better Essays
  • Good Essays

    1. Create a graph of the vapor pressure in psia of cyclohexanol, cyclohexanol and high boiler as a function of temperature from 50 to 450 F. Print and submit these graphs.…

    • 1380 Words
    • 6 Pages
    Good Essays
  • Satisfactory Essays

    The ZG traveling grate steam boilers have won the high praise form customers at home and aboard because of its significant advantages such as strong adaptability of coal and high operating efficiency,customer satisfaction is our…

    • 354 Words
    • 1 Page
    Satisfactory Essays
  • Better Essays

    Power projects are essentially capital intensive. Not only they involve a highly initial cost which is around Rs. 4.5 to 5.0 crores per MW for coal-based plants but also huge operation cost. The running expenses of a 210MW thermal power station may range around thirty crores every month and usually about 80% of this goes towards the fuel cost. Not only fuel cost but also fuel crises increasing day to day. It is therefore, very important that one gets the best performances from the installed power plants. The first criterion of performance is the plant output. Failure in generating the maximum output from the power plant implies a default in realizing the full return from the huge capital investment made for constructing the plant. Performance degradation by 1KW from a generating unit implies a net loss of about 1.2 lacks incurred over the plant operating life. The performance criterion that receives considerable attention is the plant heat rate. An increase in heat rate by a mere 1kcal/kwh reflects into direct increase in fuel cost by about Rs.20000 per day for 210MW thermal power plant. Boiler performance, the one of the main cause of heat rate deterioration from design value as its efficiency and evaporation ratio reduces with time due to poor combustion, heat transfer fouling and poor operation and maintenance. Deterioration of fuel quality and water quality also leads to poor performance of boiler.…

    • 4688 Words
    • 19 Pages
    Better Essays
  • Good Essays

    Steam Turbines

    • 458 Words
    • 2 Pages

    blades are mounted. A shaft for these wheels or drums is also a basic component,…

    • 458 Words
    • 2 Pages
    Good Essays
  • Powerful Essays

    This is to certify that seminar report entitled Working principle of Steam jet refrigeration system has been prepared by me under the supervision of Dr. Amarnath Sinha Professor of Mechanical Engg. Department N.I.T, Patna has not been submitted by me elsewhere for award of any degree…

    • 1975 Words
    • 8 Pages
    Powerful Essays
  • Good Essays

    Water and Kg 0c

    • 1949 Words
    • 8 Pages

    Condensed steam 300 C, ethanol As shown in the figure, Ethanol liquid inlet temperature = Ti=300 C. Ethanol leaves as superheated steam at 1000 C = To Heating fluid is assumed to be saturated…

    • 1949 Words
    • 8 Pages
    Good Essays
  • Good Essays

    sasasa

    • 666 Words
    • 3 Pages

    In the following requirements, an ambient temperature of 40°C (104°F) has been assumed for locations outside of boiler and engine…

    • 666 Words
    • 3 Pages
    Good Essays
  • Better Essays

    Marcet Boiler

    • 2252 Words
    • 10 Pages

    This experiment was carried out to determine the relationship between the pressure and the temperature of saturated steam in equilibrium. Besides that this experiment was also done to demonstrate the vapor pressure curve. The marcet Boiler was used for this experiment. When the pressure increases, the temperature also increases. Therefore, the relationship of pressure and temperature is directly proportional. The derived formulae and the data were used to calculate the slope. The dT/dP measured was compared with the data in the steam table. Theoretically, the values measured should be almost the same with the predicted values. However, at certain points, the values are not the same. This may because of the errors made in the experiment…

    • 2252 Words
    • 10 Pages
    Better Essays