Generator Sizing Guide - Eaton Corporation
Technical Data TD00405018E

Effective August 2009

Generator Sizing Guide

Contents
Description Page Table 1 – Motor Load Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Table 2 – Non-Motor Load Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Table 3 – Surge Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Table 4 – Fuel Pipe Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Table 5 – LP Vapor (LPV) Tank Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 UPS – Generator Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Onsite Estimating Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 System Capacity – Load Calculator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Worksheet — NEC 2008, 220 Part IV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Typical Generator/Transfer Switch

You May Also Find These Documents Helpful

  • Satisfactory Essays

    DESCRIPTION FOR THIS STUDY GUIDE: Exam Study Guide TUTORIAL: Includes final exam guide with sample answers for final exam. Individual Assignment: National Electrical Code, P1 006901 Exam Study Guide 006901…

    • 1680 Words
    • 10 Pages
    Satisfactory Essays
  • Powerful Essays

    out/electrical power in). For an electric bar heater, gas heating and wood fire, the typical COPs…

    • 1241 Words
    • 5 Pages
    Powerful Essays
  • Satisfactory Essays

    ELECTRICAL CIRCUITS 1 ELECTRICAL CIRCUITS 2 ELECTRICAL MACHINES-1 ADVANCE MACRO ECONOMICS POWER SYSTEM PROTECTION STATISTICS FOR SOCIAL SCIENCE INTERNATIONAL LOGISTICS AND SUPPLY CHAIN MANAGEMENT STRATEGIC MANAGEMENT BANK FUND MANAGEMENT SOCIETY & THE ARCH. OF BENGAL BUSINESS COMMUNICATIONS…

    • 1161 Words
    • 5 Pages
    Satisfactory Essays
  • Powerful Essays

    The following definitions have been extracted from the Electricity Glossary (Source : https://power2switch.com/glossary) and these are terminologies used in the electricity industry and will be referred to in this paper :-…

    • 2657 Words
    • 11 Pages
    Powerful Essays
  • Powerful Essays

    Increase in the energy demands has lead to techniques of combined cycle gas turbine power plants. It is evident that the demand can be met either by increasing the productivity or by making use of alternatives such as the solar energy, tidal energy, OTEC etc., but the factor of efficiency and performance must also be considered for the better utilization of input. So, comparatively to the alternative source of energy, solar energy, gas energy, nuclear energy are more efficient.…

    • 2511 Words
    • 11 Pages
    Powerful Essays
  • Good Essays

    Standards applicable:NFPA 8503 – Standard for Pulverized Fuel Systems –1997 Edition – is Obsolete and consolidated in…

    • 539 Words
    • 3 Pages
    Good Essays
  • Good Essays

    This section discusses various generator arrangements and their suitability for use in the conversion of a traditional windmill. The generator arrangement may include a speed-increasing gearbox or belt-drive and/or a power electronic frequency converter. See also the Appendix: Background information on induction generators.…

    • 730 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    Td Power Systems Pvt Ltd.

    • 369 Words
    • 2 Pages

    TDPS Generators and power plants are reputed for their impeccable performance and are approved by major consultants such as Tata Consulting Engineers, Fichtner, Holtec, Desein, M N Dastur, PDIL, Avant Garde, Mitcon, UDHE, DCPL and SPBPC.…

    • 369 Words
    • 2 Pages
    Satisfactory Essays
  • Powerful Essays

    Gas Turbine-Generator system has proximity to zero level due to absence of condenser. Therefore, Generator should have Terminal Bushings at the top of the Stator Frame. This avoids digging of tunnel / trench for routing Bus Duct and also avoids accumulation of gases from safety point of view. It was decided to develop a module THRI 108/44 for application with Gas Turbine.…

    • 1421 Words
    • 6 Pages
    Powerful Essays
  • Powerful Essays

    POM Harry paper

    • 2482 Words
    • 10 Pages

    Petoskey Power Equipment Service (Petoskey Power) is owned and operated by Harry Oldham in the North West section of New Bedford, Massachusetts. It is a one-man operation where Harry performs all aspects and functions of the business. His primary job function is to repair power tools of all types and sizes; from the most basic to the most advanced. At any time he may be working on 20 or 30 tools ranging from a simple drill that any person might have in his tool shed, to a highly intricate repair of a generator or an engine, and anything in between.…

    • 2482 Words
    • 10 Pages
    Powerful Essays
  • Good Essays

    It is highly capable of generating 5,500 watts of constant power and up to 6750 watts of startup power. 375cc OHV engine is so designed that ensures it is fuel efficient and hence…

    • 832 Words
    • 4 Pages
    Good Essays
  • Good Essays

    IEEE-30 Bus Case Study

    • 912 Words
    • 4 Pages

    The IEEE-30 bus system is used throughout this work to describe the proposed approach. It consists of six generating units, 41 transmission lines, 4 tap changing transformers and two VAR sources. The generator, bus, line, cost and emission data of the IEEE-30 bus system is taken from [27]. The one line diagram of this system is shown in Figure 5.1. The detailed system parameters are presented in the Appendix Tables A.1.Throughout all cases, the IEEE-30 bus system base MVA has assumed to be 100 MVA.…

    • 912 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Jollibee Commissary

    • 897 Words
    • 4 Pages

    Where: Jollibee Commissary, Canlubang Laguna, The Philippines What: Two 1750DQKB generator sets, powered by QSK60 engines, one 2 MW DQKC generator set, powered by a QSK60 engine and PowerCommand® Digital Master Control MC200 from Cummins Power Generation Purpose: To provide backup for the grid power supply to the food-processing plant in the event of power outages, especially during the rainy season and also during maintenance operations Primary choice factors: Product quality and reliability, air quality in compliance with emission standards, with good after-sale service…

    • 897 Words
    • 4 Pages
    Good Essays
  • Powerful Essays

    Kdpp Report

    • 5442 Words
    • 22 Pages

    KDPP is the second diesel power generating station of Kerala state electricity board. The first project is BDPP at Ernakulam. There are 8 no of generators installed in this plant and each has a capacity of 16MW. Total capacity is 128MW. Diesel engine is the prime mover of the alternator generating voltage of each alternator is 11 KV. 2 alternators are synchronized and connected in parallel in common bus bar through independent VCB at MV room and is connected to generator transformer of capacity 38 MVA, 1lkV/1l0kV.Thus there are 4 no. of GT's provided for eight engines and on service and another GT is provided for a spare at generator transformer yard .…

    • 5442 Words
    • 22 Pages
    Powerful Essays
  • Good Essays

    Bac Bac Bac-Palaw

    • 4548 Words
    • 19 Pages

    START-UP PROCEDURE (SUP)PURPOSE AND SCOPEThis procedure provides the conditions for the start-up of the Turbine- Generator of Bacman I for the following conditions: * Cold Start-up; * Warm Start-up; and * Hot Start-upThe procedure covers the activities required in the start-up of the power facility from cold, warm or hot conditions, establishment of power generation with the generator synchronized to the grid and recovery from power facility trip-outs to normal operation. DEFINITIONSCold Start-up – refers to the sequence of operations to be performed for starting up the turbine when the initial turbine metal temperature is almost equal to the ambient temperature. This condition usually happen if the turbine is shut down 4 to 6 days after a high-load operation.Warm Start-up - refers to the sequence of operations to be performed for starting up the turbine when the initial metal temperature is almost equal to 100 degree centigrade. This condition usually happen if the turbine is shut down thirty six hours after a high-load operation.Hot Start-up - refers to the sequence of operations to be performed for starting up the turbine when the initial metal temperature is above 100 degree centigrade. This condition usually happen if the turbine is shut down twelve hours or less after a high-load operation.…

    • 4548 Words
    • 19 Pages
    Good Essays

Related Topics