"Reaction between magnesium and hydrochloric acid" Essays and Research Papers

Sort By:
Satisfactory Essays
Good Essays
Better Essays
Powerful Essays
Best Essays
Page 4 of 50 - About 500 Essays
  • Good Essays

    investigation to show how the rate of reaction between hydrochloric acid and sodium thiosulphate is affected by the concentration of the acid Simple Procedure Place a conical flask on a piece of paper with a cross on it. Add hydrochloric acid and sodium thiosulphate‚ and record the amount of time taken for the cross to disappear through the solution from the top of the flask. Record this time and repeat this for different concentrations of hydrochloric acid. Fair Test The variables in this

    Premium Chemical reaction Chemistry Concentration

    • 1036 Words
    • 5 Pages
    Good Essays
  • Good Essays

    STANDARDISATION OF HYDROCHLORIC ACID REPORT Aim: To standardize an unknown solution of hydrochloric acid Method: See INSTRUCTIONS for practical 6.2 & 6.3 Results: Attempt No. | Titre (mL) | | 1 | 20.9 | Rough Titration | 2 | 20.5 | | 3 | 20.7 | Concordant Titres | 4 | 20.7 | | 5 | 20.7 | | (1) Tabled Results (2) Concordant Titrations Results 20.7 mL | 20.7 mL | 20.7 mL | Average of Concordant: (20.7 + 20.7 +20.7) 3= 20.7 mL Calculations:

    Premium Chlorine Measurement Mole

    • 524 Words
    • 3 Pages
    Good Essays
  • Good Essays

    (Fe3+ ) form. Ferric form is not usually absorbed in the body. In the stomach‚ there is low pH of 2 due to presence of gastric acids such as Hydrochloric and Ascorbic acids. These acids provide an acidic environment for reduction of ferric iron to ferrous (Fe2+). Ferrous iron can be absorbed in the body system. As in following equation of iron (iii) reaction with Ascorbic acid ‚ the product is iron (ii) chloride which is soluble 2 Fe3+ (s) + C6 H8 O6 (aq) → 2 Fe2+ (aq) + C6 H6 O6 (aq) + 2 H (aq)+

    Premium

    • 554 Words
    • 3 Pages
    Good Essays
  • Better Essays

    Investigating the rate of reaction between Marble Chips (Calcium Carbonate) and hydrochloric acid Aim. In the investigation I am going to find out how the surface area affects the rate of reaction by measuring the amount of gas produced and weight loss in a reaction between small/large pieces of Marble Chips (Calcium Carbonate) and Hydrochloric acid per minute. Hypothesis. The rate of reaction increases when the surface area of a solid reactant is increased. This happens because by

    Premium Calcium carbonate Carbon dioxide Decimal

    • 1112 Words
    • 5 Pages
    Better Essays
  • Good Essays

    Bovine Serum Albumin (BSA) then constructing a standard curve graph and to use the spectrophotometer to perform an enzyme assay using different concentration of the BSA. Experiment 5 also verifies the Beer-Lambert Law‚ which is the linear relationship between absorbance and concentration of an absorbing species. Absorbance formula is shown in fig. 1.1. However‚ the Beer-Lambert Law is not obeyed at high concentration as solution with high concentration may alter the refractive index of the solution which

    Premium Chemistry Concentration Spectroscopy

    • 690 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    oxidation-reduction reaction of magnesium and hydrochloric acid solution. We compared the experimental measured amount of a product and the amount predicted by the theoretical calculation of a balanced equation: Mg (s) + 2HCl (aq) → MgCl2 (aq) + H2 (g) PROCEDURE First we obtained a strip of pre-cut magnesium ribbon‚ cleaned it with steel wool to remove any signs of oxidation from the strip (which would alter our results)‚ and then weighed it (individual masses of the magnesium strips for each trial

    Premium Chlorine Hydrochloric acid Hydrogen

    • 880 Words
    • 3 Pages
    Powerful Essays
  • Good Essays

    To investigate how does the concentration of Hydrochloric acid affect the rate of reaction? Outline I aim to discover how different concentrations of Hydrochloric acid influence the rates of reaction. In order to carry out this investigation I have decided to use marble chips‚ which I will vary the sizes as powder‚ small chips and large chips. I will also be changing the concentration‚ the different concentrations are as follows 0.2m‚ 0.5m‚ 1m‚ 1.5‚ 2m. I have chosen these concentrations as they

    Premium Chemical reaction Hydrochloric acid Reaction rate

    • 1775 Words
    • 8 Pages
    Good Essays
  • Good Essays

    and is a strong acid. Where comparing to the conductivity of distilled water to HCL would be evidently HCL. This is because distilled water doesn’t contain ions‚ hence no movement of electrons‚ furthermore no conductivity. However since we added sodium chloride‚ distilled water will have some conductivity but no where near the amount of HCL. Comparing to the conductivity of vinegar to HCL mostly relays on how acidic each other are. Since HCL is a strong acid and vinegar is a weak acid‚ this will impact

    Premium Acid Hydrochloric acid Acid dissociation constant

    • 928 Words
    • 4 Pages
    Good Essays
  • Good Essays

    ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ______ This lab was basically about finding the percentage of acetylsalicylic acid in an aspirin tablet. First‚ the base was created‚ which was made out of 1.00 g of NaOH and D-water. Then the buret was attached to the clamp on the ring stand and the base was poured into the buret. After that‚ one by one‚ an aspirin tablet was dropped

    Premium Harvard University College John F. Kennedy

    • 1404 Words
    • 6 Pages
    Good Essays
  • Good Essays

    Hypothesis: The higher the concentration of hydrochloric acid‚ the faster the reaction will take place because there will be more hydrochloric acid particles to collide with the marble chip particles therefore resulting in a quicker reaction. The lower the concentration‚ the weaker the reaction will be as there will be fewer particles so less chance of a collision and a lower rate of reaction. Equipment: Conical flask – to hold the hydrochloric acid and marble chips Boiling tube – to hold and

    Premium Water Hydrogen PH

    • 517 Words
    • 3 Pages
    Good Essays
Page 1 2 3 4 5 6 7 8 9 50