Sodium Phosphate Monobasic Synthesis Lab Report
In experiment 3.1.We set up and calibrate the spectronic 20 first since it takes time to be ready to use so, we turned the spectronic 20 to warm up for at least 15 minutes, set wavelength to 360 while no test tube in it. Also, we set the filter lever in order to match the wavelength range, and then set the transmittance to 0%, then we changed the mode to absorbance. After we labeled two test tubes which were #5 and #10, we inserted water first to set 0 absorbance, then we used #5 sample to read it and record absorbance. At this time, we set spectronic 20 again for sample #10 by taking sample #5 out and inserted water to set transmittance to 0 then we took the water sample out and inserted #10 sample to read it and record the results. We measured the absorbance of most highly colored tube at wavelength of 360-500nm by using 20nm intervals. Then we repeated the absorbance measurement with less colored tube after we adjusted it to 0 absorbance (100%T) at each wavelength, in order to determine most reasonable wavelength which was 460nm for 2-3 experiment. …show more content…
We used 250 ml of 0.1M Sodium phosphate Monobasic, which equal 2.9995g, we added it to the 250ml beaker and added 50.0ml of water to dissolve it. On the same time, we prepared 250ml of 0.1 Sodium phosphate Dibasic, which equal to 3.549g; we added 50.0ml of water to be dissolved. We made these two solutions in order to get their PH. We started with PH 6.0 buffer from Sodium phosphate monobasic solution, we added 50ml of Sodium phosphate Dibasic to 250ml beaker, placed PH probe, then added solution Sodium phosphate monobasic until PH was between (5.9-6.1), and we called it solution

You May Also Find These Documents Helpful

  • Satisfactory Essays

    Chemistry 116 lab review

    • 289 Words
    • 2 Pages

    The first step is to calibrate the colorimeter with0.20 M Fe(NO3)3and set the absorbance at 470 nm since it is known to keep an acidic solution throughout the entirety of the experiment. It was important to do this right at the beginning of the lab since the zeroed value of the acid was the calibration number for all of the other solutions. A total of seven solutions with different dilutions were used throughout the lab to conduct the equilibrium constant. The first step was adding 5 mL of 0.200 M Fe(NO3)3to each of the 5 test tubes. Once this was done, 0.00200 M NCS was added to the test tubes, each receiving a different amount; test tube one received 1 mL NCS-and with each test tube the amount of NCS-would increase by 1 mL, test tube 5 received 5 mL of NCS. . The next step was adding HNO3 to each test tube in different volumes; Test tube one received 10 mL of HNO3 and with each test tube the amount of HNO3 decreased by 1 mL, test tube five had no HNO3 added to it. The addition of these solutions formed five test tubes of different dilutions, but of equal volume, 10 mL each. After all of the previous trials had been completed the final step was to take each test tube and pour it into a different cuvette and measure the absorbance for each. Once the initial concentration was calculated of Fe3+, NCS and FeNCS2+ in molarity. The absorbency values were recorded and used to calculate the formation constant, K f The reference table containing volumes used in each solution is provided below…

    • 289 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Tube 2 Lab Report

    • 603 Words
    • 3 Pages

    Four different temperatures were observed, including 4°C, 20°C, 32°C, and 60°C. It can be indicated that the temperature of 60°C had the highest absorbance rates (0.326 at the final time), followed by 32°C (0.179), and 4°C (0.142). With regard to 32°C and 4°C, it is noted that the tube that was 4°C initially had higher rates than the 32°C tube. Over time, the 32°C tube increased while the 4°C tube decreased, so at the end of 300 seconds, the 32°C tube had the higher absorbance rates. The 20°C tube had the lowest amount of absorbance with an absorbance rate of 0.126.…

    • 603 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Penny Lab Report

    • 2257 Words
    • 10 Pages

    Introduction: In the spectrophotometric analysis of a penny lab, we will be conducting three experiments. The purpose of the first experiment is to find the maximum absorbance on the spectrometer to obtain the optimum wavelength. Once we have gathered that information, we will use the results in the other two experiments. The purpose of…

    • 2257 Words
    • 10 Pages
    Powerful Essays
  • Satisfactory Essays

    Dye Analysis Lab Report

    • 978 Words
    • 4 Pages

    2) Based on maximum absorbance of the dye tested, select the appropriate wavelength on spectrometer.…

    • 978 Words
    • 4 Pages
    Satisfactory Essays
  • Better Essays

    Coordination Complex Lab

    • 716 Words
    • 3 Pages

    Some of the solution was removed and more deionized water (1.50mL) was added to the solution. A cuvette was filled with deionized water and another with the solution. Each cuvette was filled to the same level. The transmittance of the solution was found at 400nm and then consecutively recorded at intervals of 25nm. Absorbance was calculated from percent transmittance and then plotted on a graph as a function of…

    • 716 Words
    • 3 Pages
    Better Essays
  • Satisfactory Essays

    We collected the percent transmittance of each dilution using the SPEC20 with a wavelength of 630nm.…

    • 796 Words
    • 4 Pages
    Satisfactory Essays
  • Good Essays

    Sodium Chloride Lab

    • 739 Words
    • 3 Pages

    Looking at the three data results, sodium chloride acted more like the water. The amount difference between the total pH change between water and sodium chloride was 2.13, while the total pH change between sodium phosphate and sodium chloride was 4.08. Water has a smaller range difference to sodium chloride in comparison to sodium phosphate large range difference.…

    • 739 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    Preparation of buffer solutions 1. Activation buffer (Mixed Phosphate Buffer, pH 5.5) Solution 1: An accurately weighed quantity of 1.61 g of potassium dihydrogen phosphate was dissolved in sufficient deionized water to produce 100 mL of solution. Solution 2: An accurately weighed quantity of 35.81 g of disodium hydrogen phosphate was dissolved in sufficient volume of deionized water to produce 100 mL. Accurately measured volume of 96.4 mL of solution 1 was mixed with 3.6 mL of solution 2 to get the activation buffer. 2. Coupling buffer (pH 8.2-8.35)…

    • 552 Words
    • 3 Pages
    Satisfactory Essays
  • Good Essays

    Spinach Lab

    • 767 Words
    • 4 Pages

    To prepare the solution, 4 mL of 80% acetone was pipetted into a test tube, and five drops of the top layer of the pigment extract from the first experiment was combined with the acetone. The test tube was inverted until thoroughly mixed. Then a test tube containing 4 mL of 80% acetone was created to blank the spectrophotometer at 380 nm. The absorbance of the tube with the extract and acetone solution was then tested for its absorbency. These tests were repeated with the same solution at 40 nm intervals, until the wavelength reached 740 nm, re-blanking the machine between each test or change in wavelength. All the absorbencies were recorded, and the areas with the highest absorbance were retested at 5 nm intervals. The results were then plotted on Excel to show the relationship between certain wavelengths and the absorbance of the…

    • 767 Words
    • 4 Pages
    Good Essays
  • Better Essays

    Copper In Brass Lab

    • 1053 Words
    • 5 Pages

    One test tube was then filled half full with the same solution of nitric acid and wiped clean of finger prints and smudges. This sample was used as a blank to set the zero absorbance for the spectrophotometer. The direction of the test tube was marked and noted for future use. The student then selected a New Absorbance vs. Concentration experiment in SpectroPro. This was done in order to calibrate the spectrophotometer. The wavelength setting was set on the spectrophotometer at 620nm and the machine was set absorbance, listed as unit (A). The student set the blank to zero absorbance and finished the calibration of the spectrophotometer. The solution in the test tube was then discarded and the test tube was set…

    • 1053 Words
    • 5 Pages
    Better Essays
  • Satisfactory Essays

    H Istory O Xm Case Study

    • 630 Words
    • 3 Pages

    H istory O f Pulse O xim etry Reno Reddick W hat is a Pulse O xim etry? ▪ Non-invasive method for monitoring a patient 's O2 saturation ▪ Also measures the patient 's heart rate ▪ instant results, rather than drawing blood from a patient and examining it in a lab. H ow is it used?…

    • 630 Words
    • 3 Pages
    Satisfactory Essays
  • Satisfactory Essays

    What is the pH of the buffer that results when 12.5 g of NaH2PO4 and 22.0 g Na2HPO4 are mixed and diluted with water to 0.500 L? (The acid dissociation constants for phosphoric acid are Ka1 = 7.5  10-3, Ka2 = 6.2  10-8, and Ka3 = 3.6  10-13)…

    • 363 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    jlias sudbioa

    • 553 Words
    • 3 Pages

    Take 1 mL samples at given time points & add to tubes containing 2 mL of 0.05 M NaOH…

    • 553 Words
    • 3 Pages
    Good Essays
  • Best Essays

    Spectroscopy is the study of light. A spectrophotometer is a machine used to determine the absorbance of light at any given wavelength. It does this by using a source of white light through a prism, which gives multiple wavelengths that can be individually focused (Ayyagari and Nigam, 2007). Substances are put into cuvettes that are glass or quartz containers that light can easily travel through. The light that is being focused travels through the substance gets absorbed by the substance and is reflected back and read by galvanometer which had the ability to detect electric currents (Verma, R). The absorbance reading is then given, absorbance is usually between 0.0 – 2.0, any higher than 2.0 may mean not enough light is getting through to the galvanometer (Bhowmik and Bose, 2011). When using the spectrophotometer it is necessary to use a control or blank to zero or tare the machine in between every new wavelength or concentration, this control is water (Ayyagari and Nigam, 2007). The correlation between the numbers acquired through spectroscopy can be seen using the Beer- Lambert Law. The Beer- Lambert law states that the amount of light absorbed at a certain wavelength is proportional to the concentration of the absorbing substance (Fankhauser, 2007).…

    • 2210 Words
    • 9 Pages
    Best Essays
  • Best Essays

    The UV/Vis spectrophotometer work by passing the light by strong lamp through a monochromator, which split the light into its component colours using a gratings. Then, the desired wavelength of light beam is direct through the sample compartment which the cuvette is placed by using the mirror and slit. At other side of the compartment, there is a detector which can determine the amount of light beam pass through the solution in the cuvette, thus the absorbance of the solution in the cuvette can be determined. In addition, the absorbance of light is determined by three factors which is the nature of the solution, concentration of the solution, and the distance of light travel through the solution (path length) which stated in the Beer-Lambert Law.…

    • 2163 Words
    • 9 Pages
    Best Essays