heat CuO + H2O 4) CuO + H2SO4 Cu2+(aq) + SO42-(aq) + H2O 5) Cu2+(aq) + Zn Cu + Zn2+(aq) Stage 1- Dissolution of Copper Mass of vial & copper = 3.537g Mass of vial = 2.505g Mass of Copper = 1.032g Moles of copper = mass (g) ÷ (63.5g/mol) = 0.0162 mol (3s.f) Copper description: Initially‚ the copper was a solid that was cut into thin strips. It had a shiny/metallic and opaque look‚ with an orange colour. HNO3 description: The nitric
Premium Chemical reaction Zinc Nitric acid
Percent Copper and Formula of a Copper Compound Sofia Economides Date Preformed: 3/19/2012 Date Submitted: 3/26/2012 Lab Partners: Anita Smith‚ Taylor Bell‚ Derek Bourgeois 1. Purpose a. To determine the percent of copper and the formula weight of a copper compound. 2. Introduction a. Magnesium is a very active metal which can reduce copper (II) ions in a weight sample of a compound to metallic copper. The reduction of copper ions in a compound to a copper metal
Premium Copper Mass Hydrogen
A Sequence of Chemical Reactions: Transforming Copper Briefly describe. a) Why must you carry out the oxidation of Cu with HNO3 in a fume hood? Concentrated nitric acid is a toxic oxidant. Avoiding skin contact or inhalation is highly important. The reaction between Cu and HNO3 produces NO2‚ a toxic brown gas; therefore working under the fume is necessary in order to prevent inhaling the toxic gas. b) Why you should be particularly careful when you work with 3 M H2SO4 solution? Sulfuric acid
Premium Acid Sulfuric acid Nitric acid
Research question/Aim Extract copper from copper oxide by reduction using butane gas Hypothesis The butane gas will reduce the copper oxide and leave behind pure copper. This will allow us to find the empirical formula of the copper oxide as well as the masses of oxygen and copper Variables Dependant variable The dependant variable will be the reduction of the copper oxide which will be calculated at different temperatures. Independent variable The independent variable here
Premium Mass Heat Oxygen
factors affect the resistance of a conductor‚ and the mathematical relationship that exists between these variables. Hypothesis Copper wires would be a better conductor than nichrome wires because it would yield less resistance when they have same cross-sectional area‚ length and temperature. Resistance would be increased when length wires increased. Resistance would be increased when cross-sectional area of wires decreased. Resistivity of wires is a factor of affecting the resistance. Background information
Premium Resistivity Electrical resistance Electric current
6: The Copper Cycle CHEM 101 Lab-M/630 As an investigation of the copper cycle lab group 6 conducted an experiment on 6 October 2014 at Arizona State University laboratory that would demonstrate the cycle of reactions that copper (Cu) can produce when introduced to with other substances/reactant. The purpose of the investigation was to notice the transformation of a specific quantity of copper wire (g) as it undergoes its coordination reactions until a reduction method would yield copper (Cu) again
Premium Chemistry Copper Chemical reaction
A COMPARISON OF ALUMINUM VS. COPPER AS USED IN ELECTRICAL EQUIPMENT Larry Pryor‚ P.E. – Sr. Specification Engineer‚ GE Consumer & Industrial Rick Schlobohm‚ P.E. – Sr. Specification Engineer‚ GE Consumer & Industrial Bill Brownell‚ P.E – Specification Engineer‚ GE Consumer & Industrial ABSTRACT The debate over the pros and cons of aluminum vs. copper conductors has been discussed for many years. Many of the concerns are based on old information and also misinformation. These concerns center on the
Premium Aluminium Copper
whose resistance almost remains unchanged by increase of temperature. 2. Name two special characteristics of heater coil. 3. A wire of resistance 4 ohms is bent to form a circle. What is the resistance between two diametrically opposite ends? 4. How does the resistance of a conductor change if its temperature is increased? 5. A current of 4A flows in a wire of resistance 60 ohms. Calculate electrical energy consumed in 2 minutes. 6. V-I graph for two resistors is given. Which of the two has minimum
Premium Electricity Electrical resistance Electric current
discoveries. The latest one has been that of Fiber optic cables‚ which have gained more respect in the market than the copper cables. These cables are widely used in offices or residential areas. Copper cables transmit information through electrical signals. It has been used as a speaker system wire‚ telephone wire‚ computer cable wire etc. for over years now. Optical fiber comprises of plastic or glass strands to transmit data or information digitally with the use of light rather than electricity. On the
Premium Optical fiber
In this lab‚ we changed copper into various forms using different chemicals and chemical reactions. The purpose of this lab is to demonstrate that the product of a chemical reaction depends on what is present at the time of that reaction. This lab also displays how matter cannot be created nor destroyed in a chemical reaction. In a lab‚ you must always make safety a priority in case of an emergency. In our lab‚ we made sure to wear closed-toed shoes as well as goggles at all times. We also performed
Premium Sulfuric acid Chemical reaction Chemistry