CHM 510 LABORATORY REPORT Experiment 1: Gas Chromatography (GC): Optimization of Flow Rate and Column Temperature Name: AFIQ B. ANWAR Student No.: 2012621072 (AS2253A) Date of experiment: Date of report submission: Lecturer’s Name: PN. HALIZA Gas Chromatography (GC): Optimization of Flow Rate and Column Temperature INTRODUCTION The main purpose of the experiment is to investigate the effects of column temperature and flow rate on the separation of methyl esters compounds
Premium Chromatography Gas chromatography
Exchange Chromatography Week 10 TAG Question 1: Chapter 6-4 of your technique book provides a detailed description of how to run a ion- exchange column. Assume you have a cation-exchange column already prepared and ready to use. Create an outline of no more than 10 steps describing how you will regenerate the column‚ load your sample and collect the hydronium ion released. 1. Open the stopcock at the bottom of the column and allow solution to drain out until the solution level in the column is
Premium Hydrogen PH Erlenmeyer flask
Other Important Topics in Column Design Outline Sub-Flowsheets Thermodynamic model (Fluid Package) selection Solver selection Sub-flowsheets HYSYS has a multi-flowsheet architecture. A big flowsheet can be split up into smaller sub-flowsheets. Each sub-flowsheet has its own streams‚ operations‚ PFD and an independent fluid package. The column in HYSYS is a sub-flowsheet where independent operations are possible H83 PS1/H84 CFL Templates A template
Premium Ethanol Distillation
exchange Chromatography Ion exchange chromatography is a process for separating proteins and other molecules in a solution based on differences in net charge. Ion Exchange Chromatography relies on charge-charge interactions between the proteins in your sample and the charges immobilized on the resin of your choice. Ion exchange chromatography can be subdivided into cation exchange chromatography‚ in which positively charged ions bind to a negatively charged resin; and anion exchange chromatography‚ in
Premium Electric charge Ion Molecule
favorite candies? Chromatography can solve that for you. Chromatography is a separation technique used by scientists for separating both organic and inorganic compounds. There are four different types of chromatography: thin layer‚ liquid‚ gas‚ and paper‚ but for this lab paper chromatography will be used. Who invented chromatography? A Russian botanist named Mikhail Semyonovich Tsvet invented chromatography in 1901 while doing research on plant pigments. Why is chromatography so important? This
Premium Dye Chromatography Food coloring
Review Bubble column reactors Nigar Kantarcia‚ Fahir Borakb‚ Kutlu O. Ulgena‚* aDepartment of Chemical Engineering‚ Bog˘azic¸i University‚ 34342 Bebek-Istanbul‚ Turkey bDepartment of Chemical Engineering‚ Yeditepe University‚ 34755 Kadikoy-Istanbul‚ Turkey Received 31 August 2004; accepted 26 October 2004 Abstract Bubble columns are intensively used as multiphase contactors and reactors in chemical‚ biochemical and petrochemical industries. They provide several advantages during operation
Premium
SINGAPORE Chemical Engineering Process Laboratory II Experiment B2 Chromatography for Protein Purification Name Matric No. Group : : : Date of Expt. : GRADE : A. Learning objectives 1. 2. 3. 4. Establish chromatographic assay to determine protein concentrations in a mixture. Appreciate the importance of resolution in protein chromatography. Understand the tension between purity and yield in protein chromatography. Understand the importance of mass balance closure in protein purification
Premium Chromatography High performance liquid chromatography Protein
Gas chromatography (GC) is a chromatography technique where the separation of individual components (analytes) from a sample relies on their differing distribution between a mobile and stationary phase. The mobile phase carries the analytes through the stationary phase. In GC‚ it’s an inert gas (usually helium or nitrogen). The gas must be inert‚ so it won’t react with the sample to give a false reading. The stationary phase is a substance fixed in place to which the sample adsorbs because
Premium Temperature Thermodynamics Gas
Plant Pigment Chromatography VII. Analysis (Questions) 1. What factors are involved in the separation of pigments? Factors that are involved in the separation of pigments can include pigment solubility‚ the attraction between the pigments and paper and the size of each pigment particle. Because of these factors the results were as they were. Beta-carotene traveled the furthest because it forms no hydrogen bonds to the chromatography paper and is slightly soluble in the solvent. Contrastingly
Premium Chemistry Solubility Solvent
EXECUTIVE SUMMARY: The main objective of this project was to carry out a design on the Propane distillation column for a process that produces 1‚3 Butadiene. The raw materials used are Butane‚ Oxygen and Water and the process capacity is 100 000 tonnes per annum nominal. In the previous work it was stated that the plant is located in China. The main location of the plant is in the capital city of the Gansu Provence‚ Lanzhou. This was decided as the location over other provinces due to the excellent
Premium Distillation Chemical engineering