Unit 5 Assignment 1 Cabling Factors and Tools Discussion Week 5
Flexibility
What type of install is the cable going into? Is everything in a fixed position? If you have an install where items are moved around without being disconnected, using highly flexible cable is necessary. Cables in these scenarios need to be flexible to meet those demands of mobility, and also for the life of the wire so that it does not crack, break, fray or short. We had a job at a university where we moved flat panels on a track system to create different screen sizes, and for that we had to make sure the cable would meet the demand.
Capacitance
Cat 6 is not always better than Cat 5. If a video extender is made for Cat 5e, using Cat 6 may cause you a problem. The electrical properties are different, and the circuitry inside may not be able to reconcile the increased capacitance. You should confirm with the manufacturer before making a substitute in a Category cable.
Jacket
What type of jacket does your cable need? You have plenum, riser, PVC/non-plenum and direct burial. Plenum cable is often required in commercial work, especially in buildings where there are open-air returns; it is essential to meeting code.
Integrators will often use riser grade at the riser, and then transfer to plenum in the plenum space. This saves some cost, but I recommend you second-guess saving that few cents per foot in most cases. The chances of mixing up a box of cable and pulling riser in the plenum space may increase your liability as a company or cause you to re-pull cable when the inspector fails your install. If you only send plenum to site, you eliminate this possibility.
A tennis ball would be a good makeshift tool because you can cut a hole in it to place wires through.

You May Also Find These Documents Helpful

  • Satisfactory Essays

    NT1310 Unit 6 Exercise 1

    • 419 Words
    • 2 Pages

    On a TWISTED PAIR CABLE I chose to install an RJ-45. This is the standard Ethernet connector for most systems used today. I would first measure out the length of cable that I would need. I would then use a wire cutter to cut the length that I need, leaving enough room for corrections and to open the wire. I would then use wire strippers to remove a small piece of the outer most jacket. I would then choose what connection I wanted to make (568A or 568B). I would then untwist the wires and put them in the correct color order that I need. Then I would flatten out the wires and in one hand hold my RJ-45 connector and then with the other hand feed the wires into the connector. This is usually pretty simple with the way the connectors are made, and they are also usually clear. After I’m sure that the wires are in the connector all the way, and in the right order, I would use a wire crimper to clamp the wires securely into the connector.…

    • 419 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Unit 5 Assignment 5

    • 514 Words
    • 2 Pages

    To report security events, potential events, or other risks to the organization and its assets…

    • 514 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    Second step is to strip the outer layer from the Fiber Optic Cable with a stripping tool.…

    • 270 Words
    • 1 Page
    Satisfactory Essays
  • Good Essays

    When installing burial or aerial cable, cables containing conductive materials could pose a potential shock hazard. These types of cable shall be tested for hazardous voltage before handling. A temporary grounding and bonding harnesses shall be attached to the cable during installation. All applicable trenching, confined space, aerial, and L-T-V precautions…

    • 765 Words
    • 4 Pages
    Good Essays
  • Good Essays

    The Cat 6 cable used for these networks cannot exceed 100-meter (328 ft.) lengths in each segment. If longer sections are used, data loss starts to occur.…

    • 1081 Words
    • 5 Pages
    Good Essays
  • Satisfactory Essays

    Burying a cable keeps it out of adverse weather such as high winds, rain, snow, etc.…

    • 675 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    CER work

    • 717 Words
    • 3 Pages

    During my course studies in the university, I had to study a course called network Analysis & design. In that subject I studied how to design and install different types of cable netwroks either in exchange, building or any commercial place. I also had studied the subject management sciences, In that course, I have studied how to manage projects especially the time frame and distributing the numbers of workers in balance during the project period. As a result, I had applied this knowledge for small projects I involved in. Also, from electrical and electronic perspective, we worked with different types of cables network design practicals, and I have gained some knowledge about how they are treated and made. In some cases, those factors helped us to check the picked-up noise in those cables and wires.…

    • 717 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    in a polarity reversal test and other long-term tests aiming at high voltage operation up to 500 kV. In addition, this cable…

    • 5030 Words
    • 34 Pages
    Powerful Essays
  • Better Essays

    Shortening those cords that are just too long can be another viable option. While looking for objects to…

    • 2264 Words
    • 10 Pages
    Better Essays
  • Good Essays

    With a sharp knife, strip the outer insulation from the cable, taking care not to cut or damage the screening underneath.…

    • 811 Words
    • 4 Pages
    Good Essays
  • Powerful Essays

    Mr. Mubasher

    • 1211 Words
    • 6 Pages

    ECS Global Wire & Cable, formerly known as DME Cables, is an international distribution company that provides a complete range of wire and cable products and solutions.…

    • 1211 Words
    • 6 Pages
    Powerful Essays
  • Good Essays

    Unit 7 Assignment 1

    • 1827 Words
    • 7 Pages

    “With high obesity rates in the United States, these health care costs can directly affect employer profits.4 It is estimated that employers spend $13 billion annually on the total cost of obesity.3 Approximately 9.1% of all health care costs in the United States are related to obesity and overweight” (CDC, 2011).…

    • 1827 Words
    • 7 Pages
    Good Essays
  • Powerful Essays

    There are two types of PIJF cables in use—solid PIJF cable and foamed PIJF cable. In case of the solid PIJF cable, the conductor is insulated with solid polyethylene. This type of cable is…

    • 1270 Words
    • 6 Pages
    Powerful Essays
  • Satisfactory Essays

    3M low voltage transition cable joints (XLPE to PILC) feature the Advanced Resin Delivery System for cable jointer safety with totally enclosed mixing and pouring - preventing cable jointer contact with hazardous jointing resins and reducing spillage.…

    • 317 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Server Room Proposal

    • 438 Words
    • 2 Pages

    Structured cabling design and installation is governed by a set of standards that specify wiring data centers for data or voice communications using various kinds of cable, most commonly category 5e (CAT-5e), category 6 (CAT-6),. These standards define how to lay the cabling in various topologies in order to meet the needs of the customer, typically using a central patch panel (which is normally 19 inch rack-mounted), from where each modular connection can be used as needed. Each outlet is then patched into a network switch (normally also rack-mounted) for network use or into an IP or PBX (private branch exchange) telephone system patch panel.…

    • 438 Words
    • 2 Pages
    Good Essays

Related Topics