Preview

Global Calibration Services Market 2014-2018

Satisfactory Essays
Open Document
Open Document
309 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
Global Calibration Services Market 2014-2018
Global Calibration Services Market 2014-2018

Calibration is an operation undertaken to compare the performance of a measurement instrument against a measurement standard. Calibration indicates the traceability of the instrument and accuracy of the measured data. Industries worldwide are opting for calibration services in their production process. Calibration undertaken at regular intervals helps identifying any faults with an instrument at the earliest, reducing downtime and increases production. Calibration services include electrical, mechanical, thermodynamic, and dimensional/physical, which are used across the Industrial Manufacturing, Automotive, Aerospace and Defense, and Power industries.

Covered in this Report

This report covers the present scenario and the growth prospects of the Global Calibration Services market for the period 2014-2018. To calculate the market size, the report considers revenue generated from the services offered by the calibrators such as electrical, mechanical, thermodynamic, and dimensional/physical.

Key Regions
Europe, Middle East and Africa
The Americas
Asia Pacific

Key Vendors

Agilent Technologies Inc.
Endress+Hauser AG
Siemens AG
Trescal Inc.

Other Prominent Vendors

ABB
Danaher
GE
Micro Precision Calibration
Optical Test and Calibration
Rohde & Schwarz
SIMCO Electronics
Sulzer
Tradinco Instruments
Transcat

Key Market Driver

Demand for Onsite Calibration
For a full, detailed list, view our report.

Key Market Challenge

Need for Multidisciplinary Calibration Equipment
For a full, detailed list, view our report.

Key Market Trend
Availability of Software-based Calibration Solutions
For a full, detailed list, view our report.

Key Questions Answered in this Report

What will the market size be in 2018 and what will the growth rate be?
What are the key market trends?
What is driving this market?
What are the challenges to market growth?
Who are the key vendors in this

You May Also Find These Documents Helpful

  • Satisfactory Essays

    data driven approach

    • 269 Words
    • 1 Page

    measured by any physical quantity and the data driven approach plays a key role in the…

    • 269 Words
    • 1 Page
    Satisfactory Essays
  • Satisfactory Essays

    This industry report offers the most up-to-date market data on the actual market situation, trends and future outlook for X-ray equipment in Australia. The research includes historic market data from 2007 to 2013 and forecasts until 2018 which makes the report an invaluable resource for industry executives, marketing, sales and product managers, analysts, and other people looking for key industry data in readily accessible and clearly presented tables and graphs.…

    • 438 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    IndustryMonitor.Co announces addition of new report “Global Industrial Silica Sand Market 2012 - 2016” in it’s database. To book your copy of this report @ http://www.industrymonitor.co/report/166461-global…

    • 527 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    The article is about a survey of manufactures concerning the actual use of Gauge Repeatability and Reproducibility (GRRS) studies, and other recognized quality approaches. Specifically, the authors surveyed 30 participants of a total of 60 invited. The participants completed an online survey to determine the use and emphasis on GRRS. The survey was developed using a 5-point Likert-scale. They also used a second targeted quantitative questionnaire to determine what other techniques are used to monitor, control and improve measurement and visual inspection accuracy. A copy of the survey and questionnaire were both provided in the article’s appendix. The respondents of the survey were from companies with less than or equal to 49 employees to greater than 500 employees. 100% of all respondents reported that their company “occasionally” to “always” maintains a formalized quality system. As stated, “While this response would seem to indicate an understanding of a need for measurement improvement, the inferential statistics that the actual usage is significantly different for the perceived need”. The survey found that primary importance was placed on test equipment calibration, but a much lower importance on GRRS to validate accurate measurements and that GRRS is rarely used in visual inspection. The conclusion shows that GRRS is being used as an auditing tool and not part of a continuous quality improvement program.…

    • 377 Words
    • 2 Pages
    Satisfactory Essays
  • Satisfactory Essays

    All Market Research include new market research report "http://www.allmarketresearch.com/wiki/global-backend-as-a-service-market-2012-2016.php" to its huge collection of research reports.…

    • 413 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    analysis theory and the software error correcting technology to calibrate measurements. Besides, it gives an…

    • 1766 Words
    • 8 Pages
    Good Essays
  • Better Essays

    Physics: Sources of Errors

    • 6243 Words
    • 25 Pages

    NIST. Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, 1994. Available online: http://physics.nist.gov/Pubs/guidelines/contents.html…

    • 6243 Words
    • 25 Pages
    Better Essays
  • Satisfactory Essays

    What will the market size be in 2018 and what will the growth rate be?…

    • 368 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    GCSE Science (2014) states that accuracy is the degree of closeness a measurement of a quantity is to that quantity’s actual value. With quantitative methods, accuracy defines the limits of the errors. Ideally, a piece of apparatus (e.g. a burette in a titration) is both accurate and precise, with measurements generated close to the true value. To ensure accuracy in quantitative methods, apparatus must be calibrated, checked and analysed before use to certify that the instrument is fit for purpose. In addition, the investigator should be competent in using said apparatus and in carrying out the experiment as equipment could be misused, measurements misread and techniques performed incorrectly which results in the undermining of the accuracy and validity of a research study (Answersresearch.com, n.d.). Furthermore, repeat tests are commonly carried out and an average calculated to improve the accuracy of the results. Errors…

    • 1268 Words
    • 4 Pages
    Good Essays
  • Satisfactory Essays

    What will the market size be in 2018 and what will the growth rate be?…

    • 337 Words
    • 3 Pages
    Satisfactory Essays
  • Good Essays

    The calibrator takes over the manual metrology functions of establishing ratios and making comparisons, as well as controlling the measurement process.…

    • 897 Words
    • 4 Pages
    Good Essays
  • Good Essays

    This report analyzes the worldwide markets for Calibration Services in US$ Million by the following parameters of calibration: Mechanical Calibration Services, Electrical Calibration Services, Physical/Dimensional Calibration Services, and Thermodynamic Calibration Services. The Global market is also analyzed by the following end-use sectors: Electronic Manufacturing, Communication, Aerospace & Defence, Industrial & Automotive, and Others (includes Pharmaceuticals, Biotechnology, Medical Devices, and Food & Beverages). The report provides separate comprehensive analytics for the North America, Europe, Asia-Pacific, and Rest of World. Annual estimates and forecasts are provided for each region for the period 2007 through 2015. Also, a six-year historic analysis is provided for these markets. The report profiles 198 companies including many key and niche players such as Agilent Technologies, Inc., Dowding & Mills Plc, Fluke Corporation, GE Kaye Europe, Optical Test and Calibration Limited, Rohde & Schwarz GmbH & Co. KG, Siemens AG, SIMCO Electronics, Stork INTERMES NV, Tektronix, Inc., Sypris Test & Measurement, Inc., Tradinco Instruments B.V, Transcat, Inc., and Trescal Limited. Market data and analytics are derived from primary and secondary research.…

    • 270 Words
    • 2 Pages
    Good Essays
  • Powerful Essays

    Taylor, B. N. (2009), Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results (rev. DIANE Publishing).…

    • 3725 Words
    • 12 Pages
    Powerful Essays
  • Satisfactory Essays

    What will the market size be in 2018 and what will the growth rate be?…

    • 497 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Gbtu 3rd Year I.C Syllabus

    • 3396 Words
    • 14 Pages

    Unit 1. Topic GENERALISED CONFIGURATIONS, FUNCTIONAL DISCRIPTION & PERFORMANCE CHARACTERISTICS OF MEASURING INSTRUMENTS: Functional elements of an instrument; active & passive transducers; analog & digital modes of operation ; null & deflection methods; I/O configuration of measuring instruments & instrument system – methods of correction for interfering & modifying inputs. Static characteristics; Meaning of static calibration, accuracy, precision & bias. Combination of component errors in overall system-accuracy calculation. Addition, subtraction, division & multiplication. Static sensitivity, linearity, threshold, resolution, hysteresis and dead space. Scale readability. Span. Generalized static stiffness & input impedance. Computer aided calibration & measurement, multiple regressions. MEASUREMENT OF DISPLACEMENT, FORCE, TORQUE & SHAFT POWER: Principle of measurement of displacement. Resistive potentiometers, variable inductance & variable reluctance pickups, LVDT, capacitance pickup. Principle of measurement of Force, Torque, Shaft power standards & calibration; basic methods of force measurement; characteristics of elastic force transducer-Bonded strain gauge, differential transformer, piezo electric transducer, variable reluctance/FM-oscillator, digital systems. Loading effects; Torque measurement on rotating shafts, shaft power measurement (dynamometers). TEMPERATURE MEASUREMENT: Standards & calibration; thermal expansion methods- bimetallic thermometers, liquid-in-glass thermometers, pressure thermometers; thermoelectric sensor (thermocouple) – common thermocouple, reference junction considerations, special materials, configuration & techniques; electrical resistance sensors – conductive sensor (resistance thermometers), bulk semiconductor sensors (thermistors), bulk semiconductor sensors (thermistors); junction semiconductor sensors; digital thermometers. Radiation Methods – radiation fundamentals,…

    • 3396 Words
    • 14 Pages
    Good Essays