Chain grate steam boiler’s common water gauges
Chain grate steam boiler’s common water gauges
The water gauges should be installed to show the boiler water level timely and accurately,the following water gauges are commonly used by chain grate steam boilers:
Floating ball water level gauge

Floating ball water level gauge has hollow quartz glass ball in cavity,the ball is filled with halogen colorants.,its advantage is that the dividing line of steam and water is very clear. Its working principle is that when there is high temperature steam or boiler water in table cavity,a colorful ball will float on the liquid,and changs its location synchronously with the rise and fall of liquid level.
Plate type water level gauge
Plate type water level gauge has two types of single-sided and double-sided glass,it mainly composed by glass pane, metal frame box,steam cock,water cock,water drain valve and other components,Water gauge box box is made of cast iron, cast steel or ductile cast iron depending on the working pressure,it is also known as glass tube type water level gauge and glass plate type water level gauge.Compared with the glass tube type water level gauge,the glass plate type water level gauge can bear a higher pressure and temperature and is not easy to leak,its structure is more complex,and is widely used in boiler,the glass tube type water level gauge has simple structure and is cheap,and is widely used in small low-pressure boiler.
Bi- color water gauge
Bi- color water gauge is designed based on principles of optics,by using it, the operator can accurately determine the water level even at long distances or at night,especially when the chain grate steam boiler has a serious water shortage or overflow,it is very eye-catching with all green or all red color appearing in water table.

The ZG traveling grate steam boilers have won the high praise form customers at home and aboard because of its significant advantages such as strong adaptability of coal and high operating efficiency,customer satisfaction is our

You May Also Find These Documents Helpful

  • Good Essays

    Chem Pre-Lab

    • 635 Words
    • 3 Pages

    What buret reading should you record when the liquid level is as shown in Figure 2?…

    • 635 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Clear removable water tank The water tank is clear so that the user can see the water level. It can be removed to make filling easier and eliminates the mess and safety issues associated with pouring water directly into the tank however, this still can be done if the iron is in use when more water is needed. This feature is not found on many appliances of this type.…

    • 2539 Words
    • 8 Pages
    Good Essays
  • Satisfactory Essays

    5. Use a thermometer to record the temperature of the water in your graduated cylinder.…

    • 284 Words
    • 2 Pages
    Satisfactory Essays
  • Better Essays

    The values given in parentheses (if provided) are not standard and may not be exact…

    • 2550 Words
    • 19 Pages
    Better Essays
  • Better Essays

    column. There were two gauges, one to measure the vertical deflection and the other, the…

    • 1039 Words
    • 5 Pages
    Better Essays
  • Better Essays

    Hhou

    • 1661 Words
    • 7 Pages

    Thermometer with a cork: I am using a thermometer to take the temperate of the water. The reason I am using one with a cork attached is to keep in as much heat as possible.…

    • 1661 Words
    • 7 Pages
    Better Essays
  • Satisfactory Essays

    Boiler engineers can choose between two main types of fluidized-bed boilers—bubbling fluidized bed (BFB) and circulating fluidized bed (CFB). In BFB boilers the velocity of the combustion air is low enough that the fluidized particles remain in the lower furnace; in a CFB unit the velocity is greater and hot particles are circulated through the entire range of the boiler combustion zone. The fuel is in contact with the particles and effective mixing and combustion allows good efficiency and low emissions. Typically 97% to 99% of all burnable carbon in the fuel stream is combusted, even hard-to-burn materials. Boiler thermal efficiencies can be as high as 87% or more. Although both BFB and CFB systems are effective with biofuels, CFB is especially suitable for large boiler load ranges.…

    • 340 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Density Lab Report

    • 1162 Words
    • 9 Pages

    0.00001m³ of water is added to the cylinder and the mass of the water is measured by digital balance.…

    • 1162 Words
    • 9 Pages
    Good Essays
  • Satisfactory Essays

    Water Level Chip Scale Package – Because of its small size and its use in Wi-Fi, Bluetooth and…

    • 450 Words
    • 2 Pages
    Satisfactory Essays
  • Good Essays

    Simple Vertical Boiler

    • 761 Words
    • 4 Pages

    Simple vertical boiler consists of wall cylinder which surrounding the cylindrical fire box. Cylindrical fire box is tapped on it where steam flow to the surface. At the bottom of fire box there is grate. The fire box is equipped with two or more slope transverse pipe F, F. The slope aims to raise heating surface in addition also to improve water circulation.…

    • 761 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Every wood fired ZG boiler has been built to combine high efficiency with more cost-effective…

    • 380 Words
    • 2 Pages
    Good Essays
  • Satisfactory Essays

    are usually called DZL and SZL chain grate boiler. The chain grate boiler is often used as coal…

    • 377 Words
    • 4 Pages
    Satisfactory Essays
  • Good Essays

    Water Level Indicator

    • 2656 Words
    • 11 Pages

    Generally when we are pumping liquids like water or may be any other liquid is we need a human to see whether the tank is filled or not or we will place a overflow pipe to know that the tank is fill or not in case of water tank and we get confirmed from the water coming from overflow pipe that the has been filled. here is lots of wastage of water and still we need a human to have a look over it and so to avoid this and to save wastage of water or any other liquid that is being filled. Here is a simple circuit for liquid level alarm this circuit only tells us when the tank is full with a beep sound. It is built around two BC547 transistors (T1 and T2) and two timer 555 ICs(IC1 and IC2). Both IC1 and IC2 are wired in a stable multi vibrator mode. Timer IC1 produces low frequency, while timer IC2 produces high frequency. As a result, a beeping tone is generated when the liquid tank is full. Initially, when the tank is empty, transistor T1 does not conduct. Consequently, transistor T2 conducts and pin 4 of IC1 is low. This low voltage disables IC1 and it does not oscillate. The low output of IC1 disables IC2 and it does not oscillate. As a result, no sound is heard from the speaker. But when the tank gets filled up, transistor T1 conducts. Consequently, transistor T2 is cut off and pin 4 of IC1 becomes high. This high voltage enablesIC1 and it oscillates to produce low frequencies at pin 3. This low-frequency output enables IC2and it also oscillates to produce high frequencies. As a result, sound is produced from the speaker. Using preset VR1 we can control the volume of the sound from the speaker. The circuit can be powered from a 9V battery or from mains by using a 9V power…

    • 2656 Words
    • 11 Pages
    Good Essays
  • Good Essays

    linear measurements

    • 6532 Words
    • 66 Pages

    Sine bars are always used along with slip gauges as a device for the measurement…

    • 6532 Words
    • 66 Pages
    Good Essays
  • Good Essays

    When there is no flow in the pipe the measuring tube oscillates uniformly. In addition, sensors are located at the inlet and the outlet of the tube. These sensors have ability to notice this basic oscillation perfectly when the fluid starts to flow in the measuring tube. Additional twisting is applied on the oscillation because of the liquids inertia. As a result of Coriolis Effect, the inlet and the outlet parts of the tube oscillate in different directions simultaneously.…

    • 1222 Words
    • 5 Pages
    Good Essays

Related Topics