1. Objectives • To provide an introduction to the main features of computer aided design and analysis of power systems and the use of ERACS software package for diagram building and Load Flow analysis. • Enhance the student learning process, by relating the theory and analytical procedures to computer aided techniques for system analysis and problems solving. • To give the student the basic hands-on experience on the use of industry-based software package to simulate faulted power system.

2. Introduction

The ERACS software package comprises the following routines: a) Diagram building, Display and Reproduction (e) Harmonic Impedance (b) Load Flow (f) Transient Stability (c) Short Circuit (g) Protection Co-ordination (d) Harmonic Penetration

The first two items (a & b) form the heart of the suite which are explored in this assignment.

In this assignment, a typical power network is constructed and Load Flow Analysis is performed. Short circuit levels and Fault current levels are monitored and compared with those obtained from analytical calculations. Access to ERACS software is available in Gage Lab.

Throughout this work, you need to refer to ERACS User Guide and Technical Manual available in the Gage Lab. It is important that you familiarize yourself with the package, prior to the lab sessions, by doing the tutorial given in Chapter 3 of the User Guide. You are encouraged to keep a log book to record your progress.

3. Requirements a) ERACS Software Package. This is an industry-based software package for design and analysis of power system networks. A “user guide” and “technical manual” are available for reference. i. You will need to be familiar with the software by doing the tutorial example which will be given to you. ii. Lecture and demo sessions will be conducted by the tutor to facilitate learning.

b) Output Documents. Organize your output

You May Also Find These Documents Helpful

  • Powerful Essays

    Acc 403

    • 5361 Words
    • 22 Pages

    | Note: Instructions for using the software can be found in the Appendix of the textbook. |…

    • 5361 Words
    • 22 Pages
    Powerful Essays
  • Good Essays

    Semester 2 Assessment November 2012 Department of Electrical and Electronic Engineering ELEN20005 FOUNDATIONS OF ELECTRICAL NETWORKS Time allowed: 180 minutes Reading time: 15 minutes This paper has 28 pages including the 3-page Formulae Sheet The test is printed single-sided.…

    • 2599 Words
    • 11 Pages
    Good Essays
  • Better Essays

    D1 Unit 4 Essay

    • 1719 Words
    • 7 Pages

    Qu6. Analyse the need for selecting the different voltages used for different parts of the generation, transmission and distribution systems drawn for Qu.5.…

    • 1719 Words
    • 7 Pages
    Better Essays
  • Good Essays

    A large-scale incident that seriously impacts any part of our infrastructure is a frightening one, but considering our heavy reliance on an electrical system that utilizes antiquated and/or obsolete technology, restoring electrical service after massive disruptions (by natural or man-made causes) requires special consideration.…

    • 653 Words
    • 3 Pages
    Good Essays
  • Powerful Essays

    Different methods are used for locating. Lagrange method and two degrees gradiant and sensivity analysis method has been employed for placement [4]-[5]-[6]-[7]. This paper presents a new method for placement of DG units in distribution networks. This method is based on the analysis of power flow continuation and determination of voltage buses that are most sensitive to collapse voltage [8]. Subsequently, by selecting a objective function and using an iterative algorithm, DG units with known capacity will be installed on previously determined voltage buses. In iterative algorithm, the method of continuation power flow is used for determination of maximum loadability, thus it is needed to study the impact of different DG technologies on static voltage stability. This method will be executed on a typical 34-Bus test system. II-The impact of different DG technologies on Voltage Stability A. Synchronous Generator Conventional synchronous generators are capable of both generating and absorbing reactive power. Therefore, the use of DG’s utilizing overexcited synchronous generators will allow on-site production of reactive power. The local generation of…

    • 3723 Words
    • 15 Pages
    Powerful Essays
  • Best Essays

    En.wikipedia.org (2011) Electrical grid - Wikipedia, the free encyclopedia. [online] Available at: http://en.wikipedia.org/wiki/Electrical_grid [Accessed: 19 Jun 2012].…

    • 2109 Words
    • 9 Pages
    Best Essays
  • Powerful Essays

    Smart Grid Vision to India

    • 8726 Words
    • 35 Pages

    Certified that this a bonafide record of the seminar work “ SMART GRID AND VISION FOR INDIA” by KODANDA RAM R B P U S B (Roll:12206109), submitted to the faculty of Electrical and Electronics Engineering, in partial fulfillment of the requirements for the award of degree in MASTER OF TECHNOLOGY in Power Systems from K L UNIVERSITY, Greenfields, Vaddeswaram.…

    • 8726 Words
    • 35 Pages
    Powerful Essays
  • Powerful Essays

    Instrumentation Lab

    • 1511 Words
    • 7 Pages

    * Get familiar with the pressure gages, such as U tube manometer , deadweight and calibrate them with pressure gage .…

    • 1511 Words
    • 7 Pages
    Powerful Essays
  • Best Essays

    Thermal Power Plant

    • 3142 Words
    • 13 Pages

    References: * Lakhoua MN. SCADA applications in thermal power plants. International Journal of the Physical Sciences Vol. 5(6), pp. 1175-1182, June 2010…

    • 3142 Words
    • 13 Pages
    Best Essays
  • Powerful Essays

    The Engineering Technology and Industrial Distribution Department at Texas A&M University is pursuing an initiative to integrate curriculum from Electronics Engineering Technology, Mechanical and Manufacturing Engineering Technology and Nuclear Engineering to create a Power Engineering Technology program. In addition to developing new courses for this path of study, existing courses are being redeveloped. In the Electronics Engineering Technology Program, the Instrumentation and Control Systems course is being restructured to focus on a systems-level development process. In the power industry, master and multi-slave control over a standardized architecture is a prime example of changes in the program. A team enrolled in the Instrumentation and Control Systems course has undertaken a project to develop a system which will be used to facilitate the laboratory requirement for this course. This project will also provide a reference design for future students learning similar communication systems.…

    • 3898 Words
    • 16 Pages
    Powerful Essays
  • Powerful Essays

    The field I intend on undertaking is electric power which is concerned with the design and operation of systems for generating, transmitting, and distributing electric power. Engineers in this field have brought about…

    • 1671 Words
    • 7 Pages
    Powerful Essays
  • Powerful Essays

    On the following pages is an example of a formatted paper which follows the guidelines set forth in Parts 2 and 3 of…

    • 1543 Words
    • 7 Pages
    Powerful Essays
  • Good Essays

    miss

    • 1226 Words
    • 5 Pages

    from generation to load centres. This is due to a number of technical reasons the…

    • 1226 Words
    • 5 Pages
    Good Essays
  • Good Essays

    IEEE-30 Bus Case Study

    • 912 Words
    • 4 Pages

    The IEEE-30 bus system is used throughout this work to describe the proposed approach. It consists of six generating units, 41 transmission lines, 4 tap changing transformers and two VAR sources. The generator, bus, line, cost and emission data of the IEEE-30 bus system is taken from [27]. The one line diagram of this system is shown in Figure 5.1. The detailed system parameters are presented in the Appendix Tables A.1.Throughout all cases, the IEEE-30 bus system base MVA has assumed to be 100 MVA.…

    • 912 Words
    • 4 Pages
    Good Essays
  • Powerful Essays

    Earthing

    • 1086 Words
    • 5 Pages

    In the early power systems were mainly Neutral ungrounded due to the fact that the first ground fault did not require the tripping of the system. An unscheduled shutdown on the first ground fault was particularly undesirable for continuous process industries. These power systems required ground detection systems, but locating the fault often proved difficult. Although achieving the initial goal, the ungrounded system provided no control of transient over-voltages.…

    • 1086 Words
    • 5 Pages
    Powerful Essays