Preview

column chromotagraphy

Good Essays
Open Document
Open Document
500 Words
Grammar
Grammar
Plagiarism
Plagiarism
Writing
Writing
Score
Score
column chromotagraphy
Ferrocene and Acetylferrocene will be separated using column chromatography.

Column chromatography is a separation technique that is used among many disciplines including biology, biochemistry, microbiology and medicine. Many common antibiotics are purified by column chromatography.1 Column chromatography allows us to separate and collect individual compounds. In this experiment, lumen will be the stationary phase, and the more polar substance will be retained on the stationary phase longer.
To start out the experiment, a short pipette which was used as the column was prepared. A small paper plug was placed loosely in the bottom of the column and then approximately ½cm of sand was added. After that, 6 cm of Alumina were added to the column, making sure that it settles evenly, and it was then topped off with another ½ cm of sand. The column was then attached to a ring stand using a clamp. Two watch glasses where then weighed and labeled. Approximately 2cm depth of Heptane to the top of the column was added. The entire F: AF solution was added immediately to the top of the column once the liquid level drained down and reached the top of the sand. When the F: AF solution dropped into the sand, heptane was added to the top of the column making sure it did not dry. The yellow band was collected in the first watch glass. Once all of the yellow band had eluted, the watch glasses were switched and when the heptane level reached the top of the sand, we switched to MTBE (methyl t-butyl ether). The MTBE was continued to be added to the column to elute the orange band. Both of the watch glasses were placed in a fume hood where the solvent was allowed to evaporate, afterwards, the watch glasses were weighed again. A developing chamber by outfitting a 100 mL beaker, and a watch glass for a lid was then prepared. Dveloping solvent was added to the chamber to a depth of no more than ½ cm. The mobile phase for ferrocene:acetylferrocene is 30:1 toluene :

You May Also Find These Documents Helpful

  • Good Essays

    During the same time, the flask was warmed on a sand bath in order to dissolve the solid. Then it was allowed to slowly cool to room temperature and placed into an ice bath for 10 minutes. The crystals were collected by vacuum filtration and were allowed to dry.…

    • 618 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    * Add 2 g of alum crystals to crucible. Weigh crucible, cover, and crystals and record mass in data table.…

    • 1639 Words
    • 7 Pages
    Satisfactory Essays
  • Good Essays

    1. Paper Chromatography is a method used for the separation of colors which are also referred to as colored chemicals/substances or pigments. This method is used for experiments, to identify coloring agents and to separate out a compound into its various components.…

    • 815 Words
    • 3 Pages
    Good Essays
  • Good Essays

    2. Measure out 25 to 45 grams of one of the four metals on the trough. This may require several "clicks."…

    • 1598 Words
    • 7 Pages
    Good Essays
  • Good Essays

    Chromatography

    • 884 Words
    • 4 Pages

    The chromatography lab is to understand how molecules with similar molecular properties can be separated with paper chromatography. These differences will be interpreted to see the distinction of separate chemical substances.…

    • 884 Words
    • 4 Pages
    Good Essays
  • Good Essays

    Chromatography serves mainly as a tool for the examination and separation of mixtures of chemical substances. Chromatography is using a flow of solvent or gas to cause the components of a mixture to migrate differently from a narrow starting point in a specific medium, in the case of this experiment, filter paper. It is used for the purification and isolation of various substances. A chromatographically pure substance is the result of the separation. Because purification of substances is required to determine their properties, chromatography is an indispensable tool in the sciences concerned with chemical substances and their reactions.…

    • 521 Words
    • 3 Pages
    Good Essays
  • Satisfactory Essays

    Chem Lab 2 Report

    • 942 Words
    • 9 Pages

    Procedure: In the experiment, I use devices such as a ruler, beakers, flasks, a scale and cylinders to measure the values of each object and liquid.…

    • 942 Words
    • 9 Pages
    Satisfactory Essays
  • Good Essays

    5.05 Ink Chromatography

    • 748 Words
    • 3 Pages

    The purpose of this laboratory investigation is to observe how chromatography can be used to separate mixtures of a solution.…

    • 748 Words
    • 3 Pages
    Good Essays
  • Good Essays

    • Take the filter paper with the crystals out of the funnel and place on a watch glass. Label the wash glass and place on the tray dry before placing on balance to weigh.…

    • 614 Words
    • 3 Pages
    Good Essays
  • Good Essays

    (1) Metric ruler with centimeter (cm) and millimeter (mm), (1) table salt, (1) small number of ice cubes, (1) piece of string, (1) isopropyl (rubbing) alcohol, (1) tap water, (1) distilled water, 25 mL, (1) paper, 5 cm x 5 cm for weighing chemicals, (1) colored drink, (1) beaker, 100 mL, glass (1) burner-fuel, (1) burner-stand, (1) cylinder, 25 mL, (1) 23-mL volumetric flask, (1) Pipet, Serological 2mL, (1) Bulb, Rubber (1) Goggles-Saftey, (1) Scale-Digital-500g, (1) Test Tube (1), 13 x 100 mm, (1) Thermometer, (1) Bolt, (1) Magnet bar, (1) Pipet, Empty Short Stem…

    • 2216 Words
    • 9 Pages
    Good Essays
  • Satisfactory Essays

    Click and drag a piece of weighing paper with the powdered substrate to a test tube.…

    • 470 Words
    • 3 Pages
    Satisfactory Essays
  • Better Essays

    To start this experiment, 0.200g of (E) Stilbene, white salt like compound with no specific aroma, were added to a round bottom flask weighting 17.73g. Then 4mL of cold acetic acid, clear liquid with vinegar smell, were also added to the flask and the mixture with a flea stir bar was placed in sand bath for around 12 minutes until the (E) Stilbene was completely dissolved. Pyridinium tribromide (0.394g), a bright red powder, was added to the mixture, resulting in a fast change in the coloration of the first mixture from clear to an orange/brown liquid. The new reaction was placed back to the sand bath and the dark orange color, which was expected to fade, changed colors from first a light yellow to a cloudish yellow color with a bright yellow layer on top. This reaction occurred in a period of 7.5 minutes at constant stirring. After the time indicated by instruction was completed, 4mL of cold DI water were added in order to increase the polarity and agitate the precipitate without dissolving the sample. After this addition the mixture turned completely white with notorious solid at the bottom. This solid formed in the flask was collected through vacuum filtration with a Hirsch…

    • 1023 Words
    • 5 Pages
    Better Essays
  • Powerful Essays

    Prior to the experiment, a 600 mL capacity glass beaker was obtained from the front of the laboratory. The beaker was weighed on a digital scale and its mass was determined to be 213.7 grams. A galvanized iron nail and a lump of steel wool was then collected from the front of the laboratory and the zinc coating on the iron nail was rubbed off using the steel wool. The iron nail was then weighed on a digital scale and its mass was determined to be of 6.5 grams. Two tablespoons of copper(II) chloride (CuCl2) crystals were then added to the beaker. The copper(II) chloride crystals were blue in colour, shown in Figure 1 below.…

    • 1905 Words
    • 9 Pages
    Powerful Essays
  • Good Essays

    Column chromatography was invented by Tswett in 1906 so that his study of the chemistry of chlorophyll could be facilitated. Tswett made significant advances in the method and demonstrated its applicability to the separation of many different kinds of mixtures. Column chromatography rapidly found application in all areas of chemistry and is used extensively today because it is a simple but powerful tool for the separation of pure compounds from a complex mixture. It cannot affect the same degree of separation as TLC, but its advantage over TLC is the fact that large amounts of mixtures (over 5 g) can easily be treated by this method. There are, however, a number of important similarities between TLC and column chromatography which, when the two methods are used in complementary fashion, allow preparative separations to be accomplished easily and quickly. The same comments that were made concerning adsorbents and solvents for TLC apply also to column chromatography. In particular, by using TLC initially to determine a solvent system for separation of a mixture, one can quickly find the solvent system that will effect separation of the same mixture on a column of the same adsorbent. (In other words, if a particular solvent system effects separation on, say, alumina with TLC, a very similar solvent system will effect separation of a column, provided that alumina of the same type is used as adsorbent.…

    • 721 Words
    • 3 Pages
    Good Essays
  • Good Essays

    Chromatograph method is a method of separating mixtures of two or more compounds. Two phases are important in this method; one that is stationary and one that is moving. Chromatography works on the principle that different compounds will have different solubilities and adsorption to the two different phases between which are to be partitioned. Thin Layer Chromatography (TLC) is a solid-liquid technique. The mixture is observed when it is in two different phase; a solid (stationary phase) and a liquid (moving phase). Thin Layer Chromatography (TLC) is a technique which is sensitive, cheap and fast. A thin layer chromatograph plate is used to identify drug component under UV. It is used to support the identity of a compound in a mixture when the Rf of a compound is compared with the Rf of a known compound.…

    • 522 Words
    • 3 Pages
    Good Essays